It's time to calibrate your touch-screen!


Since the Spire Photo Booth has two screens, during the calibration process we will to manually define the calibration surface.

Note: if you prefer, you can disconnect the back screen OR select "show only 1/2" in the display settings, and calibrate in Normal Mode.


Before you start with the calibration process, make sure your touch screen is connected directly to the computer's USB port.


[Can't see the video? Click here to watch on YouTube]


Instructions:


1. Download the XT Controller driver from here and open the application.


2. Right click anywhere on your desktop > Display settings > Set the "Multiple displays" to "Duplicate these displays".


3. Open the XT Controller app, click on "Graph" and set the Threshold to 7.


4. Click on "Raw" and "Test TP".


5. Click "Calibrate" and select "Area mode".


6. With your keyboard's mouse, define the calibration area (press and hold your mouse, from one corner to the opposite). Then release and Save the area.


7. Touch the circles until they fill up green to finish the calibration process.